logo
バナー バナー
ニュース詳細
Created with Pixso. ホーム Created with Pixso. ニュース Created with Pixso.

High-Voltage PTC Heaters for EV Platforms: How to Choose 400V, 600V or 800V

High-Voltage PTC Heaters for EV Platforms: How to Choose 400V, 600V or 800V

2026-11-27

By EVLINK Engineering Team

Choosing a high-voltage PTC heater for EV platforms starts with the battery's minimum and maximum voltage: the heater's operating range has to cover both. Suppose the battery maker specifies a working range of 560–760 V. Selection of the 600 V heater would leave the fully charged pack above the heater's upper limit of 750 V. Selection of the 800 V heater would leave the discharged pack below its lower limit of 600 V. Neither standard heater covers this particular battery.

How to Interpret the Voltage Range in a Heater Datasheet

With a working range of 620–740 V the outcome is different. Both ends of the battery range lie inside the 600–750 V interval common to the two heaters. Either is eligible on voltage grounds. The two battery examples are hypothetical. The heater ratings used for comparison are those shown in the table.

Heater rating Permitted bus voltage (±25%)
600 V DC 450–750 V DC
800 V DC 600–1000 V DC

Operating voltage ranges for 600 V and 800 V PTC coolant heaters, showing their shared 600–750 V DC range.

Rated voltage is the value assigned to the heater for continuous service and used in its insulation design. The operating range specifies the permissible variation, ±25% for the standard versions in the table. The designation "600 V" on a traction battery gives neither the upper nor the lower pack voltage. A choice between the 600 V and 800 V heaters therefore requires the battery manufacturer's data. The same applies to a heater for a 400 V vehicle.

Which data should the battery manufacturer supply? For the lower limit, the condition of interest is a substantially discharged battery delivering a high load at low temperature. For the upper limit, establish the maximum at full charge, including operation on a fast charger. Obtain the tolerance associated with each figure. Packs with the same nominal voltage may differ in the number and chemistry of the cells connected in series, or in the charging strategy.

High-Voltage Bus and Platform Voltages

A single kilowatt at 12 V requires approximately 83 A. A heater rated in kilowatts therefore takes its DC supply directly from the high-voltage bus, without an intermediate DC-DC converter. Although 400 V and 800 V are familiar designations, a 600 V-class system is common in electric buses, and trucks often operate in the 600–800 V range. The suitability of the 800 V architecture for fast charging is discussed in our article on 800V PTC coolant heaters.

Silver cab-over tractor with a blue curtain-sided semitrailer outside a warehouse on wet pavement.

Four Items for the Component Specification

Item Information required
Battery Minimum and maximum voltage at the heater supply, with tolerances and the operating condition for each limit
Heater supply circuit Cabin and battery heat demand, current for that demand (I = P / U) and the heater's current profile on a cold start
Insulation Minimum insulation resistance, voltage at which it is measured, withstand voltage, creepage and clearance specified by the OEM. ISO 6469-3 addresses electrical safety against shock in the vehicle's high-voltage circuits.
Control Allocation of fault protection between heater and vehicle. EVLINK CAN models provide overvoltage and undervoltage protection, automatic power limiting and fault self-diagnosis.

The allocation is different for the E-series PTC coolant heater and N series. Both use a thermostat and have neither an external control input nor a communications interface. The thermostat is the listed high-voltage protection. The vehicle's high-voltage circuit should therefore provide overcurrent and short-circuit protection.

Power Rating and Circuit Current

The table gives an indication of the current involved in supplying the same heating duty at different nominal bus voltages. The values have been calculated from I = P / U on the assumption that full rated power is available at nominal voltage. They are not measurements made by EVLINK and do not include the effects of switching on or of variation in the battery voltage.

Heat load At 400 V At 600 V At 800 V
10 kW 25.0 A 16.7 A 12.5 A
24 kW 60.0 A 40.0 A 30.0 A

For a given power, doubling the supply voltage from 400 V to 800 V halves the current. The designer may retain the same conductor resistance and reduce wiring losses, or consider a smaller cable and connector. Cable, connector, fuse and contactor selection must also allow for the starting characteristic. The resistance of a cold PTC element is lower than its resistance in normal service. For a heater with soft start, use the current profile obtained with that function in operation.

An increase in bus voltage also affects the space needed for insulation. Check the applicable insulation resistance, withstand voltage, creepage and clearance requirements. A longer creepage path occupies space, while additional insulation or potting can introduce resistance to heat transfer. Where the power per unit of element area increases, the heat-transfer surface must be sufficient to limit the operating temperature of the element and the associated aging.

Interpreting a Supplier's Stated Output

A power figure is useful only in conjunction with the conditions at which it was obtained. Specify the same supply voltage, inlet coolant temperature and coolant flow rate for each quotation, including a test point at the minimum battery voltage. The rate at which heat leaves the element affects its temperature and hence its resistance and output.

Also establish the response to reduced coolant flow, a stopped pump and a failed sensor. In normal service the rise in PTC resistance with temperature limits the current. It does not provide disconnection in the event of a fault. Independent protection against overtemperature, overcurrent, overvoltage and undervoltage must be identified and tested.

Can one heater serve both 400 V and 800 V platforms?

The standard EVLINK 800 V heater has a minimum supply voltage of 600 V, which places a 400 V battery outside its range. A common part can be considered only if the entire working window of each battery is within the heater manufacturer's specified limits.

EVLINK High-Voltage PTC Heaters for EV Platforms

The table summarizes our main series of high-voltage PTC heaters for coolant loops. 1100 V DC custom versions are available for the Q series.

Item EVLINK
Main series 1–35 kW
Standard ratings 600 V or 800 V DC (customizable)
Standard operating range ±25% of rated voltage
Higher-power option S series, 100 kW
Other platforms Matching models available for the 400 V class
Control arrangement Series and power range
Thermostat N: 1–3 kW
E-series PTC coolant heater: 20–24 kW
CAN communication with enable signal W, Z: 3–8 kW
K: 5–12 kW
H: 8–14 kW
A: 8–18 kW
B: 15–24 kW
Q: 15–35 kW
CAN communication with enable signal, plus percentage power or temperature PID control F35: 35 kW (customizable)
Relay, or CAN through an external control board S: 100 kW

The S series is the exception to the standard voltage window above. Its rating is 800 V DC and its operating range is 550–1000 V DC.

Coolant heater specifications

Specification Value
Enclosure IP67
Insulation resistance, high-voltage section ≥100 MΩ at 1000 V DC
Operating temperature −40 °C to 85 °C
Overvoltage, undervoltage, overcurrent, short-circuit and overheat protection CAN-controlled A, B, H, K, Q, W, Z and F35
Warranty 2-year warranty

EVLINK's A, B, K, Q and W series hold E-Mark type approval under UN ECE Regulation No. 10 (EMC).

For flow, pressure drop, coolant inlet temperature and CAN protocol information, contact us and specify which configuration you are considering. Those details depend on the project.

JiuXing Energy truck project

FAQs

Can a 400 V battery supply an 800 V PTC heater?

Not within its specification. For the EVLINK 800 V standard version, the specified range is 600–1000 V DC. A 400 V battery cannot reach the 600 V minimum. The CAN-controlled units have undervoltage protection, but no heating performance is specified below that minimum. For a 400 V vehicle, ask about the available 400 V-class heaters.

What is the operating voltage range of a 600 V PTC heater?

Take the tolerance from the manufacturer's datasheet. For EVLINK standard versions it is ±25%, giving 450–750 V DC for the 600 V version. Where the battery exceeds 750 V on charge, the 800 V version (600–1000 V DC) is a possible alternative provided the battery remains at or above 600 V on discharge.

Does an 800 V PTC heater give higher thermal efficiency than a 400 V heater?

At the element, almost the whole electrical input is converted into heat in either case. The distinction is in transmission of power to the heater. At 800 V, half the current is required for the same duty. This permits lower wiring losses and gives scope for smaller cables and connectors, subject to the higher insulation requirements.

Can EVLINK supply a heater for 1100 V service?

Yes. 1100 V DC custom versions are available for the Q series. The other main series are offered at 600 V or 800 V DC (customizable). Send us the battery's minimum and maximum voltage and the heating power required, and we will check whether it fits.

Conclusion

Start from the battery manufacturer's minimum and maximum voltage, with tolerances, and check both against the heater's operating range. Current, insulation and control follow from that choice.

Planning a high-voltage heating project? Share your vehicle type, HV platform voltage, required heating power, control method (CAN or thermostat), connector preference, coolant flow and inlet temperature, and installation space. EVLINK's engineering team will recommend a matching heater configuration. Request a quote →

About EVLINK

EVLINK designs and manufactures high-voltage PTC heaters for electric commercial vehicles in Kunshan, China. Its main PTC coolant heater series cover 1–35 kW for 600 V and 800 V DC platforms with IP67 protection. EVLINK's quality management system is certified to IATF 16949:2016, and its products are exported to more than 65 countries.

References